FND-7000 Defibrillator
Defibrillator
Application Scenarios:
Defibrillator is a medical device that utilizes a stronger pulse current through the heart to eliminate arrhythmia and restore sinus rhythm, and it is a necessary first aid equipment in all hospital departments. Defibrillation is one of the important steps for performing CPR
Products advantage:
Battery Level Indicator:To monitor the battery real time
Biphasic Technology:With impedance compensation More effective Less Energy and less hurt to the heart
Internal Thermal Printer:50mm integrated thermal recorder
Data Storage:65 hours of all measured parameters
Paddle:Charging and shocking can be easily operated through according buttons;Quickly converted from adult to pediatric by removing the outer surface
Technical Specifications:
Display Type: 8 inch high resolution LCD display
Sweep Speed: 25mm/sec
Information: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.
Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, , II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.Heart Rate:20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable
Smart Alarms: Beeper/voice prompts indicate shockable rhythm.
Battery
Type: Rechargeable,Ni-MH battery,12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.
Additional parameters will effect operating time with different functions.
AED Mode
AED Function: Auto analyze and charge X3 with programmable auto energy level selection.
screen prompts.and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm,and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel, press key on paddle.
Prompts: Voice and visual prompts.


Accessory Standard |
|
ECG cable |
1Pcs |
Battery |
1Pcs |
AED pads |
1Pcs |
blood oxygen probe |
1Pcs |
Thermal paper |
1Pcs |
ECG pads |
1Pcs |
AED Pads Tie line |
1Pcs |
Power supply cable |
1Pcs |
Grounding line |
1Pcs |
Product model |
Box size |
Gross weight |
FND-7000 |
45*41*40cm/1pcs |
10kg |
Related videos
Related Products
Related articles