iMAC1800 High-end 18-Ch ECG Machine
iMAC1800
High-end 18-Ch ECG machine
32000 Hz Sampling Rate and 24 Sampling Data of each channel
Digital Sampling Rate:32000Hz
A/D Conversion: 24 bits
1s baseline stability
Frequency Response:0.01-350 Hz
Support double-pole pacemaker detection
Support thermal folded paper
TM Original iFilter adaptive filtering technology has greatly improved the ECG signal quality
Glasgow ECG analysis algorithm
ST segment elevation myocardial infarction diagnosis ability is in the industry leading position
Support advanced analysis function like VCG, Time VCG,VLP etc
As world first 18-channel resting ECG machine, the iMAC1800 greatly
increases the detection rate of right ventricular and posterior wall
myocardial infarction.
Effectively solved the clinical problems that normal 12-channel ECG machine cannot
observe more parts at the same time. Effectively improve the accuracy and timeliness of
myocardial infarction and myocardial ischaemia diagnosis
32〇〇〇 Hz Sampling Rate and 24 Sampling Data of each channel
Digital Sampling Rate:32000Hz
A/D Conversion: 24 bits
1 s baseline stability
Frequency Response:0.01 -350 Hz
Support double-pole pacemaker detection
Supportthermal folded paper
Original iFilter™ adaptive filtering technology has greatly improved the ECG signal quality Glasgow ECG analysis algorithm
ST segment elevation myocardial infarction diagnosis ability is in the industry leading position Support advanced analysis function like VCG, Time VCG^LP etc
Recording weak signal accurately
Waveform Comparison
AHA and CSE database Certified
Auto analysis validation results | ||||||||
P-wave time limit (ms) | PR Interval (ms) | QRS Complex (ms) |
QT Interval (rns) |
|||||
Average Deviation |
Standard Deviation |
Average Deviation |
Standard Deviation |
Average Deviation |
Standard Deviation |
Average Deviation |
Standard Deviation |
|
iMAC results | 0.5 | 9.3 | -1.9 | 7.0 | 0.1 | 4.9 | 4.5 | 12,2 |
IEC60601-2-51 latest requirement | ±10 | 15 | ±10 | 10 | ±10 | 10 | ±25 | 30 |
Glasgow algorithm efficiently improves the accuracy of the measurement and credibility of auto-analysis
More specific than cardiologists unsporting STEMI
Diagnosis utilizes gender
Diagnosis utilizes age
Diagnosis utilizes race
Diagnosis utilizes medication history
Support advanced analysis function like VCG, Time VCG,VLP etc.
Innovative Ergonomic Design
Three-pronged ECG Leads, Effectively reduce winding
Trolley
Support connecting with HIS, EMR, PACS and other hospital information system without PC work station
RELATED PRODUCTS
DOWNLOAD
Company Name:
Nanjing FoiNoe Co.LTD
Company Address:#15- 403, No.52 Fengyousi Street,Qinhuai district, Nanjing, Jiangsu, China
CONTACT US
Office Phone: 86-25-52337951
Company Fax: 86-25-52337952
Contact Person: Bob Jiang (Export Manager)
Email: foinoe@foinoe.com foinoe@hotmail.com
Online chat:
Skype: foinoe
Whatsapp: +8618061881266
Viber: +8618061881266