Number of views:
1000

PM-8000A

Retail price
0.0
Market price
0.0
Product serial number
Quantity
-
+
Stock:
Specification
Parameters
Video
Image
Package
FAQ

PM-8000A

Multi-parameter Patient Monitor

Monitor ECG, RESP, $po2, NIBP TEMP PR and HR

Yonker is one of the biggest medical and healthcare product manufacturers in China.

Range of product: Patient monitor, Pulse oximeter, Blood pressure monitor,

Thermometer, Fetal Doppler, UV radiation, etc.

The whole production line is medical CE certified and mostly FDA certified.

TECHNICAL SPECIFICATIONS

Quality Standards

CE.ISO13485,SO9001

Design patent certification

Application Range

Adult/Pediatric/Neonatal/Medicine/Surgery/

Operating Room/ICU/CCU

Display

7’real color TFT screen

Environment

Operating environment:

Temperature: 0-40℃

Humidity: 15%-80%

Pressure: 86.0 kpa-106。0kpa

Transport and Storage environment

Temperature: -20-55℃

Humidity: 10%-90%

Pressure: 86.0 kpa-106。Okpa

Power Requirements

AC:100~240V,50Hz/60Hz

DC: Built-in rechargeable battery

Battery: 11.1V 24wh Li-ion battery

2h operating after full charge

5min operating after low battery alarm

Dimension and Weight

Equipment

175mm x 140mm x300 mm; 3.3 kg

Package:

360mm×250mmx300mm; 4.5kg

ST segment

ST Segment Range: -2.0mv-+2.0mv

Accuracy 0.02mV

Spo2

Measurement range: 0-100%

Resolution 1%

Accuracy: 70%-100% 土2%

40%~69%±3%

Pulse Rate

Measure/alarm range: 20- 300bpm

Resolution 1bpm

Accuracy ±3bpm

Displayed Parameters

Time: Battery-backed quartz crystal clock

ECG: ECG Waveform Scale, displayed lead

Heart Rate: Derived from ECG or Spo2

NIBP: Pressure (systolic, mean and diastolic

Pulse Oximeter: Pulse Rate, Spo2 waveform, and

Oxygen saturation

Respiration Rate: Respiration rate derived from ECG

Trends: HR, RR, NIBP, TEMP and Spo2

Temperatures: one channels

ECG

5 Leads: RA. LA. LL RL. V

Lead mode:I,Ⅱ,Ⅲ,AVR,AVL,AVF,V

Gain: x 1.25mm/mv. 2.5mm/mv

5.0mm/mv 10mm/mv

20mm/mv (error<=5%)

Sweep speed: 6.25mm/s, 12. 5mm/s, 25mm/s

50mm/s (error s 土10%)

Bandwidth: Surgery 1-25 HZ

Monitor 0.5-40 Hz

Diagnostic 0.05- 130 HZ

Sensitivity: >200 uV P-P

CMRR:>=112db

Differential Input Impedance: >5M

ohm Electrode Offset Potential: 土300mv

Polarization Voltage:≥±500mV

nput Impedance:≥5M

Calibration Voltage: 1mv土5%

RESP

Method: impedance between RA-LL

Resp Impedance range: 0.3-3Ω

Base Impedance range: 200Ω-4000Ω

Bandwidth: 0.3-2.5HZ

Gain:×0.25.×0.5.×1.×2.×4

Resp rate

Measurement Range

Adult

0-120BRPM

Neonatal/Pediatric 0- 150BRPM

Resolution 1BRPM

Accuracy: 7-150brpm(土2BRPM)

0-6brpm(unspecified)

Apnea Alarm: 10-40s

NIBP

method Oscillometry

Measure mode Manual Auto STAT

Measure interval in auto mode

1-5/10/15/30/60/90/120/180/240/480min

Measure period in STAT mode: 5min

Pulse rate range. 40-240bpr

Measure &alarm range: Adult

SYS 40-280mmhg

DIA 10-220mmhg

MEAN 20-240mmhg

Pediatric

SYS 40-220mmHg

DIA 10-160mnHg

MEAN 20-170mmhg

Neonatal

SYS 40~135mmH

DIA 10-100mmhg

MEAN 20-110mmhg

Static pressure measurement

Range:

0-300mmhg

Accuracy ±3mmH

Resolution: 1mmhg Accuracy

Max. Mean Error:±5mmHg

Ma. Standard Deviation: 8mmhg

Overpressure protection

Adult 300mmhg

Pediatric 240mmhg

Neonatal 150mmhg

TEMP(optional)

Channel 1

Measure&alarm range: 0-50℃

Resolution 0.1℃

Accuracy(no sensor): 土0.1℃(0-50℃)

Standard accessories

NIAP cult tube

ECG cable electrodes

Spo2 sensor

Lithium-ion battery

Power cable

Operators manual

Optional accessories

TEMP probe (skin)

Trolley bracket

Hanging bracket

Monitor recorder

Vehicle-mounted power supply

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
Previous
Next

RELATED PRODUCTS

There is currently no content to display
Please add data record on website background.

DOWNLOAD

There is currently no content to display
Please add data record on website background.
留言应用名称:
客户留言
描述:
验证码
Nanjing FoiNoe Co. Ltd

Company Name:

Nanjing FoiNoe Co.LTD


Company Address:#15- 403, No.52 Fengyousi Street,Qinhuai district, Nanjing, Jiangsu, China

CONTACT US

Office Phone:  86-25-52337951
Company Fax:  86-25-52337952
Contact Person:  Bob Jiang (Export Manager)

Email: foinoe@foinoe.com    foinoe@hotmail.com

 

Online chat:

Skype: foinoe

Whatsapp: +8618061881266

Viber:   +8618061881266

PRODUCTS

底部版权

Time of issue:2019-07-17 00:00:00
Copyright © 2020 Nanjing FoiNoe Co. Ltd  POWER BY:300.cn 苏ICP备19053485号-1