DM7000 Defibrillator Monitor
DM7000 Defibrillator Monitor
Display
⚫ Display Type: 8 inch high resolution LCD display
⚫ Sweep Speed: 25mm/sec
⚫ Information: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Se— lection and Limits, Delivered Energy
Defibrillator
⚫ Waveform: Biphasic
⚫ Charge Time: Less than 7 seconds with a new fully charged battery
⚫ Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts.
⚫ Electrode Impedance Measurement Range: 0—250 ohms
ECG Monitoring
⚫ Patient Connection: 5—lead ECG cable, or 3—lead ECG cable, paddles.
⚫ Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V
⚫ ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor
⚫ Heart Rate: 20—300BPM
⚫ Heart Rate Alarm: On/Off displayed on monitor, user—selectable.
⚫ Smart Alarms: Beeper/voice prompts indicate shockable rhythm
Recorder
⚫ Paper: 50mm thermal.
⚫ Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User—selectable 6—second delay.
⚫ Printing Method: High—resolution, thermal print head.
⚫ Print—out Modes: Manual or automatic, user—configurable.
⚫ On/Off Control: Front panel and paddle.
⚫ Automatic Function: 9—seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge
Battary
⚫ Type: Rechargeable, Ni—MH battery, 12V.
⚫ Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.
⚫ Additional parameters will effect operating time with different functions.
AED Mode
⚫ AED Function: Auto analyze and charge X3 with programmable auto energy level selection,screen prompts, and voice prompts.
⚫ Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm,and QRS complex wave duration >=140ms.
⚫ Charge Control: Control on device front panel, press key on paddle.
⚫ Prompts: Voice and visual prompts
Manual Mode
⚫ Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
⚫ Synchronized Mode: Synchronizes defibrillator pulse to patient's R—wave. "SYNC" message displayed on monito
Specification | pacer (Optional) |
Type | VVI |
Pulse Type | rectanguIar,constant current |
Pulse Amplitude | 0 to 180 mA + 10% or 5 mA (whichever is greater). |
Pacing Rate | Variable from 30 ppm to 180 ppm +1.5% (increments or |
decrements by a value of 2 ppm) | |
Multi-Function Electrode (MFE)Pads | multipurpose defibrillation/pacing electrodes |
Pause | Pacing pulse frequency reduced by a factor of 4 when |
activated | |
Refractory Period | NC(VVI demand do not have this specification) |
Pulse Width | (20+ 1.5 ms) |
Output Protection | Fully defibrillator protected and isolated |
Specification | EtCO2 (Optional) |
Type of sensor | By-pass |
Technical principle | Non-dispersiveinfraredgas analysis NDIR |
Storage condition | -40 °C to 70°C, <90% RH, non-condensing |
Operating conditions | 5 °C to 50 °C, 10 to 90% RH, non-condensing |
Ambient pressure | 55-115kPa |
Power supply | 5 V+5% (max ripple 200 mVp-p) |
TDP | Typical vaIue120mA Excursion calibration typical |
value280mA | |
Range | 0-19.7% (0—150mmHg,or 0-20kPa) |
Resolution | 0.1mmHg |
0 - 40 mmHg + 2 mmHg | |
Accuracy | 41 - 70 mmHg + 5% ofreading |
71 - 100 mmHg + 8% of reading | |
101 - 150 mmHg + 10% of reading | |
Respiratory rate | 2-150 BPM |
Respiratory rate measurement | 1 +1BPM |
accuracy | |
Measurement unti: | mmHg/kPa |
mmHg/kPa | Pediatric:10 200 mmHg/kPa |
Neonatal: 10 135 mmHg/kPa | |
Resolution | 1 mmHg |
Accuracy: | Maximum mean error:5 mmHg Maximum standard deviation:8 mmHg |
Type of sensor | By-pass |
Technical principle | Non-dispersive infrared gas analysis NDIR |
Storage condition | -40 °C to 70°C, <90% RH, non-condensing |
Specification | NIBP (Optional) |
Operating conditions | 5 °C to 50 °C, 10 to 90% RH, non-condensing |
Ambient pressure | 55-115kPa |
Power supply | 5 V +5% (max ripple 200 mVp-p) |
TDP | Typical value 120mA Excursion calibration typical value 280mA |
Range | 0-19.7% (0—150mmHg,or 0-20kPaJ |
Resolution | 0.1mmHg |
Accuracy | 0 - 40 mmHg + 2 mmHg |
41 - 70 mmHg + 5% of reading 71 - 100 mmHg + 8% of reading | |
101 - 150 mmHg + 10% of reading | |
Respiratory rate | 2-150 BPM |
Respiratory rate | 1 % +1BPM |
measurement accuracy | |
Specification | SPO2 Moudle (Optional) |
Measurement Range | 30 100%,+2% between 80% 90%,Others +5% |
Alarm Range | User set high limit and low limit |
Alarm Accuracy | +10 within setting values |
Alarm Time Accuracy | Less than 12 sec. |
n monito
RELATED PRODUCTS
DOWNLOAD
Company Name:
Nanjing FoiNoe Co.LTD
Company Address:#15- 403, No.52 Fengyousi Street,Qinhuai district, Nanjing, Jiangsu, China
CONTACT US
Office Phone: 86-25-52337951
Company Fax: 86-25-52337952
Contact Person: Bob Jiang (Export Manager)
Email: foinoe@foinoe.com foinoe@hotmail.com
Online chat:
Skype: foinoe
Whatsapp: +8618061881266
Viber: +8618061881266
底部版权
- COVID-19
- Whatsapp +8618061881266
- E-mail foinoe@foinoe.com
- Call +86-25-52337951
- Top