DM7000 Defibrillator Monitor
Number of views:
1030

DM7000 Defibrillator Monitor

Retail price
0.0
Market price
0.0
⚫ Battery Level Indicator ⚫ Biphasic Technology ⚫ Internal Thermal Printer ⚫ Data Storage ⚫ Charging and shocking can be easily operated through according buttons ⚫ Quickly converted from a dult to pediatric by removing the outer surface
Product serial number
Category
Medical
Quantity
-
+
Stock:
0
Specification
Parameters
Video
Image
Package
FAQ

DM7000 Defibrillator Monitor

DM7000 Defibrillator Monitor

Display

⚫ Display Type: 8 inch high resolution LCD display 

⚫ Sweep Speed: 25mm/sec

⚫ Information: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Se— lection and Limits, Delivered Energy

Defibrillator

⚫ Waveform: Biphasic

⚫ Charge Time: Less than 7 seconds with a new fully charged battery

⚫ Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts.

⚫ Electrode Impedance Measurement Range: 0—250 ohms

ECG Monitoring

⚫ Patient Connection: 5—lead ECG cable, or 3—lead ECG cable, paddles.

⚫ Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V

⚫ ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor

⚫ Heart Rate: 20—300BPM

⚫ Heart Rate Alarm: On/Off displayed on monitor, user—selectable.

⚫ Smart Alarms: Beeper/voice prompts indicate shockable rhythm

Recorder

⚫ Paper: 50mm thermal.

⚫ Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User—selectable 6—second delay. 

⚫ Printing Method: High—resolution, thermal print head.

⚫ Print—out Modes: Manual or automatic, user—configurable.

⚫ On/Off Control: Front panel and paddle.

⚫ Automatic Function: 9—seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge

Battary

⚫ Type: Rechargeable, Ni—MH battery, 12V.

⚫ Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.

⚫ Additional parameters will effect operating time with different functions. 

AED Mode

⚫ AED Function: Auto analyze and charge X3 with programmable auto energy level selection,screen prompts, and voice prompts.

⚫ Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm,and QRS complex wave duration >=140ms.

⚫ Charge Control: Control on device front panel, press key on paddle.

⚫ Prompts: Voice and visual prompts

Manual Mode

⚫ Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules. 

⚫ Synchronized Mode: Synchronizes defibrillator pulse to patient's R—wave. "SYNC" message displayed on monito

Specification pacer (Optional)
Type VVI
Pulse Type rectanguIar,constant current
Pulse Amplitude 0 to 180 mA + 10% or 5 mA (whichever is greater).
Pacing Rate Variable from 30 ppm to 180 ppm +1.5% (increments or
decrements by a value of 2 ppm)
Multi-Function Electrode (MFE)Pads multipurpose defibrillation/pacing electrodes
Pause Pacing pulse frequency reduced by a factor of 4 when
activated
Refractory Period NC(VVI demand do not have this specification)
Pulse Width (20+ 1.5 ms)
Output Protection Fully defibrillator protected and isolated
Specification EtCO2 (Optional)
Type of sensor By-pass
Technical principle Non-dispersiveinfraredgas analysis NDIR
Storage condition -40 °C to 70°C, <90% RH, non-condensing
Operating conditions 5 °C to 50 °C, 10 to 90% RH, non-condensing
Ambient pressure 55-115kPa
Power supply 5 V+5% (max ripple 200 mVp-p)
TDP Typical vaIue120mA Excursion calibration typical
value280mA
Range 0-19.7% (0—150mmHg,or 0-20kPa)
Resolution 0.1mmHg
  0 - 40 mmHg + 2 mmHg
Accuracy 41 - 70 mmHg + 5% ofreading
  71 - 100 mmHg + 8% of reading
  101 - 150 mmHg + 10% of reading
Respiratory rate 2-150 BPM
Respiratory rate measurement +1BPM
accuracy
Measurement unti: mmHg/kPa
mmHg/kPa Pediatric:10 200 mmHg/kPa
Neonatal: 10 135 mmHg/kPa
Resolution 1 mmHg
Accuracy: Maximum mean error:5 mmHg Maximum standard deviation:8 mmHg
Type of sensor By-pass
Technical principle Non-dispersive infrared gas analysis NDIR
Storage condition -40 °C to 70°C, <90% RH, non-condensing
Specification NIBP (Optional)
Operating conditions 5 °C to 50 °C, 10 to 90% RH, non-condensing
Ambient pressure  55-115kPa
Power supply 5 V +5% (max ripple 200 mVp-p)
TDP Typical value 120mA Excursion calibration typical value 280mA 
Range 0-19.7% (0—150mmHg,or 0-20kPaJ
Resolution  0.1mmHg
Accuracy 0 - 40 mmHg + 2 mmHg
41 - 70 mmHg + 5% of reading 71 - 100 mmHg + 8% of reading
101 - 150 mmHg + 10% of reading
 
Respiratory rate  2-150 BPM
Respiratory rate  1 % +1BPM
measurement accuracy
Specification SPO2 Moudle (Optional)
Measurement Range 30 100%,+2% between 80% 90%,Others +5%
Alarm Range User set high limit and low limit
Alarm Accuracy +10 within setting values
Alarm Time Accuracy Less than 12 sec.

n monito

Keyword:
Defibrillator
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Previous
Next

RELATED PRODUCTS

There is currently no content to display
Please add data record on website background.

DOWNLOAD

There is currently no content to display
Please add data record on website background.
留言应用名称:
客户留言
描述:
验证码
Nanjing FoiNoe Co. Ltd

Company Name:

Nanjing FoiNoe Co.LTD


Company Address:#15- 403, No.52 Fengyousi Street,Qinhuai district, Nanjing, Jiangsu, China

CONTACT US

Office Phone:  86-25-52337951
Company Fax:  86-25-52337952
Contact Person:  Bob Jiang (Export Manager)

Email: foinoe@foinoe.com    foinoe@hotmail.com

 

Online chat:

Skype: foinoe

Whatsapp: +8618061881266

Viber:   +8618061881266

PRODUCTS

底部版权

Time of issue:2019-07-17 00:00:00
Copyright © 2020 Nanjing FoiNoe Co. Ltd  POWER BY:300.cn 苏ICP备19053485号-1