Micro infusion pump

Micro infusion pump
  • ID: 111212405816
  • Product Name:Micro infusion pump
  • Product Origin:Jiangsu,China
  • Payment Terms:T/T, L/C, D/P
  • Price Terms:FOB, CFR, CIF

Product detail

Application
Continuous micro-infusion in the ICU and CCU
Maintenance therapy micro-infusion and blood transfusion in premature infants and neonates
Injection of s
Continuous injection of anesthetics
Injection of oxyfocics
Injection of anticoagulants during dialysis and extracorporeal blood circulation
For anti cancer drugs
Range of body weight mode
Dose rate   0.01-99.99µg/kg/min (0.01µg/kg/min increments)
                   0.01-99.99mg/kg/h (0.01 mg/kg/h increments)
Body weight 0.1-300kg (0.1 kg increments)
Drug volume 0.1-999.9 mg (0.1 mg increments)
Solution volume 0.1-999.9 ml (0.1ml increments)
Other Functions
Body Weight Mode (Only for WZ-50C6T)
OCCLUSION pressure selected
Anti bolus
Syringe brands selected
Automatically recognize syringe size
Preset Limited volume
Total volume indicate
KVO
Fast-injection control
Lock the fast key when infusing
Lock the flow rate keys when infusing
Audio and Video alarms
AC and DC indicate
RS232 part
Warm of wrong operation
500 log
 
PERFORMANCE  PARAMETER  
Flow rate
0.1ml/h --1200ml/h                                      50ml syringe
0.1ml/h --600ml/h                                       30ml syringe
0.1ml/h –399.9ml/h                                      20ml syringe
0.1ml/h –300.0ml/h                                      10ml syringe
(0.1ml/h increments, above 1000ml/h 1ml increments)
Purge
1200ml/h (50ml syringe)
600.0ml/h (30ml syringe)
399.9ml/h (20ml syringe)
300.0ml/h (10ml syringe)
Occlusion pressure
800mmHg±200mmHg(H)(106.7kpa±26.7kpa)
500mmHg±100mmHg (C)(66.7kpa±13.3kpa)
300mmHg±100mmHg (L)(40.7kpa±13.3kpa)
Precision
≤±2% (Drive accuracy≤±1%)
Total volume
0.1-9999ml
Preset limited volume
0.1-9999ml
Alarm
START reminder; near empty(NEA.EMPTY); empty; syringe disengaged; syringe dislocated; internal malfunction; occlusion; output volume equals to preset volume; battery under-voltage; battery exhausted; AC power failure; repeat alarm.
Power
AC230V, 50/60HZ (European Union) 
Internal Battery: 12V±2V
The pump can run continuously over 3 hours @5ml/h under normal conditions using internal battery after it is fully charged.
Operating condition
Temperature: +5℃~+40℃
Relative Humidity: 20%~90%
Transportation and storage conditions:
Temperature: -40℃~+55℃
Relative Humidity: ≤95 %
Classification
ClassⅠ
type CF
IP×4 ,belongs to splash-proof equipment
External dimension
349(L)×185(W)×128(H)mm
N.W.
3.2 KG
Syringe
Syringe size: 10ml/20ml/30ml/50ml
Syringe type:13kinds of disposable syringe brands can be used

Product Image